Re: [Amel Yacht Owners] Onan Generator Troubles
Stephen MORRISON <steve_morrison@...>
Duane. I had these very same codes and my generator often shut down within the first two minutes of running. I had Cummings come out and look it over and it turned out to be the exhaust sensor. A little fumbling with the wires and it has run smooth ever since. I did order a spare sensor to have on hand but the Cummings service guy said I could also just connect the wires directly and bypass the sensor as a fix if needed as in his opinion, so long as water was running through, which has its own sensor, the exhaust cannot get hot enough to be a problem. All the best, Steve Morrison SM380 Brunswick .
On Apr 23, 2017, at 11:01 AM, sailor63109@... [amelyachtowners] <amelyachtowners@...> wrote:
|
|