Re: Watermaker looses pressure
Germain Jean-Pierre
Hi Carina & Conny,
toggle quoted message
Show quoted text
I have a Duo 100 as well and have had this exact issue from time to time. I deal with it as follows: - I let the pressure vary and if the system goes to overpressure (OP), it shuts down anyways. - If the problem stated above occurs, I go to the filter clean valve and clean the filters because in OP, the automatic clean function does not occur. - Use it a lot… it will stabilise after about 15 hours of production. Mohammed’s suggestion is spot on; Martijn De Jong is top caliber (I think he is the creator/eengineer of the Duo 60 & 100) GL and big hugs, Jean-Pierre & Julie, Eleuthera SM007
|
|