Re: A54 fridge circulation pump
Oliver Henrichsen, SV Vela Nautica
Hello, My VESC gets its 24V power from 24V Emgine room point. It gets serial bus commands from an ARM32 MCU. My system takes temperatures from inside freezer, fridge, compressor fridge, compressor freezer, raw water temperature in its calculation to controll all cooling needs. It adapts the raw water cooling pump speed according to sea water temperature and compressor temp. This might be over kill but provides the most efficient operation. As you got already digital controlls you may only like to switch the cooling pump. It would be still possible to adjust the motor speed to raw water temp. If you cant setup your own controller I could provide a unit, based on my software, adapted to digital thermostats. My unit also writes a protocoll of the operating times of fridge / freezer and temperature curve with alarms. Oliver from Vela Nautica Amel54 #39 Martinique
On Wed, Feb 5, 2020, 13:54 Jamie Wendell <mysticshadow54@...> wrote: Oliver, I just ordered the Censored Motor and VESC Controller from AliExpress. I am going to try to hook all this up and see if I can get it to work for my 3-fridge system.
|
|