Re: A55: fresh water pump system : Beam IV


michael winand
 

Great to hear that you have most likely found the problem. If you still have a flow problem it is likely to be a partial blockage where the water is distributed. If so. I would back connect a hose to flush the circuit. 

On Sat, 29 Feb 2020 at 5:00 am, Stuart Hemingway
<stuart@...> wrote:
Thank you Michael,

That should be the next procedure to investigate . 

Confusingly the deck hose and the transum shower have good pressure.

  

Stuart Hemingway AA Dipl DMS RIBA


Symbiotic Relationships Ltd.,


 Grove Park Studios,

188-192 Sutton court Road,

Chiswick,

London,

W4 3HR

 

Telephone

From the UK  :    001 561 371 2321

From the US  :    561 371 2321


E . Studio@...

W. www.groveparkstudios.co.uk.


On 27 Feb 2020, at 17:45, michael winand via Groups.Io <mfw642000@...> wrote:

Just a thought. 
If you have a leak on the suction side it will allow air to enter the water pipes and this won't compress enough to reach the shut off pressure. 
Michael. Nebo sm251


On Thu, 27 Feb 2020 at 10:39 pm, CW Bill Rouse
<brouse@...> wrote:
Stuart,

I gave you all of my ideas. Like I said before I don't think the accumulator tank pressure has anything to do with a continuous running pump. 


Best,

CW Bill Rouse 
Amel Owners Yacht School
+1 832-380-4970 | brouse@...
720 Winnie, Galveston Island, Texas 77550 
www.AmelOwnersYachtSchool.com 
Yacht School Calendar: www.preparetocastoff.blogspot.com/p/calendar.html


   

On Tue, Feb 25, 2020, 5:08 PM Stuart Hemingway <stuart@...> wrote:
Hello Joerg & Bill,

Who ever thought you’d need a bicycle pump on a boat , but you do!

We bought this fancy cycle pump in Bonaire ( the old fashion type would be better ) pumped up the accumulator and we have water!!

THANK YOU 

The pump is still running continuously though any ideas on that one?

Very best regards & thanks ..

Stuart

Stuart Hemingway AA Dipl DMS RIBA


Symbiotic Relationships Ltd.,


 Grove Park Studios,

188-192 Sutton court Road,

Chiswick,

London,

W4 3HR

 

Telephone

From the UK  :    001 561 371 2321

From the US  :    561 371 2321


E . Studio@...

W. www.groveparkstudios.co.uk.


On 25 Feb 2020, at 01:53, Joerg Esdorn via Groups.Io <jhe1313=yahoo.com@groups.io> wrote:

In my experience, there has to be nothing wrong to create this condition.   I’ve had this happen on my boat when I get back after many months away.  Or if the tank was run very low.   Pump up the tank and see whether it works.  Cheers. Joerg 

Joerg Esdorn
A55 #53 Kincsem
Vigo, Spain