Re: New Thread on A54 fridge pumps (ATTN: OLIVER Vela Nautica)
Here is the schematic showing that the power to the Frigoboat E51385 interface (Blue Box) comes directly from the Fan Output on the Danfoss compressor controller (1 of the 3 circled in red): This is out of a Frigoboat Manual" which states the Fan Output terminals always output 12 volts regardless of whether the unit is connected to 24 volts or 12 volts.