Re: Climma Air Conditioning from shore power


 

Thanks, Peter.

As expected, proof that the Ground Fault cause was seawater intrusion into the Calpeda Motor Stator as a result of a mechanical seal failure in the pump housing coupled with a missing Slinger Washer.

The good news is that the pump lasted more than 20 years. I believe if the Slinger Washer had been on the shaft that you would have noticed the leak from the mechanical seal early enough to own that pump for another 20 years. Calpeda makes a great pump.

Bill


CW Bill Rouse Amel Owners Yacht School
Address: 720 Winnie, Galveston Island, Texas 77550 
View My Training Calendar


On Tue, Feb 16, 2021 at 3:08 PM Peter de Groot <pandmdegroot@...> wrote:

Here’s the conclusion
Thanks all for your help and suggestions
Saludos
Peter
La Querida SM 207
Barra de Navidad, Mexico