Re: New Engine alignfment in a SM
Sula is SM 140. These are the mounts removed from under the old volvo. I presume originals. They are by Schwartz and googling that and the numbers brings up very little. I am awaiting a reply from
Sula is SM 140. These are the mounts removed from under the old volvo. I presume originals. They are by Schwartz and googling that and the numbers brings up very little. I am awaiting a reply from
|
By
Graham Boyd
·
#45495
·
|
|
Re: New Engine alignment in a SM
Hi Bill thanks again.
We are going to machine a false coupling plate and follow the rest of your instructions and Olivier's as well. Could you forward any drawings you may have that would help. my
Hi Bill thanks again.
We are going to machine a false coupling plate and follow the rest of your instructions and Olivier's as well. Could you forward any drawings you may have that would help. my
|
By
Graham Boyd
·
#45494
·
|
|
Re: Marco Pump stoppage
Duane,
Glad you havewater pumping again.
Keep in mindthat PR is a part of the USPS and you can Express Mail or Priority Mail (2-3days) to the island from most USA online chandleries at regular
Duane,
Glad you havewater pumping again.
Keep in mindthat PR is a part of the USPS and you can Express Mail or Priority Mail (2-3days) to the island from most USA online chandleries at regular
|
By
Mark Erdos
·
#45493
·
|
|
Re: Marco Pump stoppage
Hello Duane,
I went through the same process 2 years ago. My chosen replacement pump is a Marco 12E.
It is more compact than the original and as it is a constant pressure pump, I did not bother with
Hello Duane,
I went through the same process 2 years ago. My chosen replacement pump is a Marco 12E.
It is more compact than the original and as it is a constant pressure pump, I did not bother with
|
By
Germain Jean-Pierre
·
#45492
·
|
|
Re: Marco Pump stoppage
Follow up:
After checking for a blockage, lack of voltage, or lack of water, the manual says the only other thing to check is the motor brushes.
I took the back cover off and one motor brushholder
Follow up:
After checking for a blockage, lack of voltage, or lack of water, the manual says the only other thing to check is the motor brushes.
I took the back cover off and one motor brushholder
|
By
Duane Siegfri
·
#45491
·
|
|
CloudStreet is for sale
Hi All,
CloudStreet is for sale. She is a 2001 Amel Super Maramu 2000 in excellent condition with many upgrades. I have put up a website with the particulars and also posted to the 'Amel for Sale'
Hi All,
CloudStreet is for sale. She is a 2001 Amel Super Maramu 2000 in excellent condition with many upgrades. I have put up a website with the particulars and also posted to the 'Amel for Sale'
|
By
Joe Nance
·
#45490
·
|
|
Reya water pump pressure switch
Hello all,
I still have the original Reya fresh water pump on BeBe and over the years the pressure achieved has slowely decreased. In 2017 it would switch off automatically at about 33 psi on the
Hello all,
I still have the original Reya fresh water pump on BeBe and over the years the pressure achieved has slowely decreased. In 2017 it would switch off automatically at about 33 psi on the
|
By
Dan Carlson
·
#45489
·
|
|
Re: Mizzen Mast Access
It is probably better to use an electrical lubricant to pull the wires. Less corrosive and much more slick.
It is probably better to use an electrical lubricant to pull the wires. Less corrosive and much more slick.
|
By
Stephen Hancock
·
#45488
·
|
|
Re: Mizzen Mast Access
Hi Gary,
The wires in the Mizzen seem to get wrapped around each other.
Upon inspection a few years ago I noticed that all the pull lines were in bad shape so I replaced them with dyneema. It is
Hi Gary,
The wires in the Mizzen seem to get wrapped around each other.
Upon inspection a few years ago I noticed that all the pull lines were in bad shape so I replaced them with dyneema. It is
|
By
eric freedman
·
#45487
·
|
|
Re: Mizzen Mast Access
Gary,
When I had torun an additional cable for a new radar unit, it took a lot of finesse.Attaching the new wire to the older one and pulling it down the mast did notwork. There is some sort of
Gary,
When I had torun an additional cable for a new radar unit, it took a lot of finesse.Attaching the new wire to the older one and pulling it down the mast did notwork. There is some sort of
|
By
Mark Erdos
·
#45486
·
|
|
Mizzen Mast Access
OK, I am at an impasse with my mizzen mast. We haven't quite gotten to the arbitration stage yet, but we have a situation of a stubborn lack of cooperation.
My trusty wind generator threw a blade a
OK, I am at an impasse with my mizzen mast. We haven't quite gotten to the arbitration stage yet, but we have a situation of a stubborn lack of cooperation.
My trusty wind generator threw a blade a
|
By
Gary Wells
·
#45485
·
|
|
Re: Marco Pump stoppage
Ok, got it.
Duane
By
Duane Siegfri
·
#45484
·
|
|
Re: SM Climma AC - Calpeda Pump Voltage with Breakers Off
Hi Bill and Eric:
Yes, all the 220 panel CBs are double pole (both Line [brown] and Neutral [Blue] are switched). With all breakers open (tripped) there is still 240 VAC across the blue and brown
Hi Bill and Eric:
Yes, all the 220 panel CBs are double pole (both Line [brown] and Neutral [Blue] are switched). With all breakers open (tripped) there is still 240 VAC across the blue and brown
|
By
Gary Silver
·
#45483
·
Edited
|
|
Re: Marco Pump stoppage
Duane,
The reset button is only on the electronic control module. Go back and read my email.
Best,
CW Bill Rouse
720 Winnie St
Galveston Island, TX 77550
+1(832) 380-4970
Duane,
The reset button is only on the electronic control module. Go back and read my email.
Best,
CW Bill Rouse
720 Winnie St
Galveston Island, TX 77550
+1(832) 380-4970
|
By
CW Bill Rouse
·
#45482
·
|
|
Re: Marco Pump stoppage
Thanks for the replies to Bill and Tony. Unfortunately my pump does not have a reset button...I don't see on in the manual either. Maybe the larger ones have one.
I'm going to check for blockages in
Thanks for the replies to Bill and Tony. Unfortunately my pump does not have a reset button...I don't see on in the manual either. Maybe the larger ones have one.
I'm going to check for blockages in
|
By
Duane Siegfri
·
#45481
·
|
|
Re: Marco Pump stoppage
Duane,
If you have the electronic control module (which I strongly recommend to my clients), the following are the instructions you need. If you do not have the electronic control module, I believe
Duane,
If you have the electronic control module (which I strongly recommend to my clients), the following are the instructions you need. If you do not have the electronic control module, I believe
|
By
CW Bill Rouse
·
#45480
·
|
|
Re: Marco Pump stoppage
I will post the reset instructions by tomorrow.
Best,
CW Bill Rouse
720 Winnie St
Galveston Island, TX 77550
+1(832) 380-4970
I will post the reset instructions by tomorrow.
Best,
CW Bill Rouse
720 Winnie St
Galveston Island, TX 77550
+1(832) 380-4970
|
By
CW Bill Rouse
·
#45479
·
|
|
Re: SM Climma AC - Calpeda Pump Voltage with Breakers Off
Bill,
I will be on Kimberlite next week and check.
Fair Winds
Eric
Kimberlite Amel Super Maramu #376
Bill,
I will be on Kimberlite next week and check.
Fair Winds
Eric
Kimberlite Amel Super Maramu #376
|
By
eric freedman
·
#45478
·
|
|
Re: Marco Pump stoppage
Hi Duane
I had a similar situation with my Marco. The following is the advice from Marco’s engineer. The scenario / process was omitted from my manual in error and has now been included by Marco.
Hi Duane
I had a similar situation with my Marco. The following is the advice from Marco’s engineer. The scenario / process was omitted from my manual in error and has now been included by Marco.
|
By
tony wells
·
#45477
·
|
|
Re: SM Climma AC - Calpeda Pump Voltage with Breakers Off
Not sure. I also don't remember any blue wires on those breakers.
Best,
CW Bill Rouse
720 Winnie St
Galveston Island, TX 77550
+1(832) 380-4970
Not sure. I also don't remember any blue wires on those breakers.
Best,
CW Bill Rouse
720 Winnie St
Galveston Island, TX 77550
+1(832) 380-4970
|
By
CW Bill Rouse
·
#45476
·
|